IBM 6866 Personal Computer User Manual


 
Iomega Zip Drive Test
Use the Iomega Zip Drive Test to test the zip drive and the
drive interface. The test takes about 20 seconds to run.
The default tests the following:
Controller
Max Seek (50 times)
Random Seek (300 sectors)
Asset EEPROM backup
When replacing a system board, this utility allows the
backup of all Asset information from the EEPROM to
diskette. This utility also restores data to the EEPROM
from diskette after replacement of the system board.
To run this utility:
Select Utility
Select Asset EEPROM Backup
follow instructions on screen.
Viewing the test log
Errors reported by the diagnostic test will be displayed by
the program as a failed test.
To view details of a failure or to view a list of test results,
do the following from any test category screen:
Press F3 to activate the log File
Press F3 again to save the file to diskette or F2 to
print the file.
RIMM memory errors: SIMM/DIMM/RIMM error
messages issued by the IBM PC Enhanced Diagnostics:
Important
If the failing RIMM pairs are not identified by the
diagnostics, replace individual RIMM on the memory
board one at a time until the diagnostics run with out
error.
Message Failure Found Recommended
Actions
2xx-1y
(for SIMMs)
A memory error
was detected in
SIMM socket Y
Replace the
SIMM in the
socket identified
by the last digit of
the error code.
Re-run the test.
If the same error
code occurs
again, replace
the system
board.
138 IBM PC 300/IntelliStation Vol 3 HMM