IBM 6866 Personal Computer User Manual


 
Diagnostic Error Code FRU/Action
014-196-XXX
Parallel port test halt, error
threshold exceeded
1. Depress F3 to review
the log file.
2. Re-start the test to
reset the log file.
014-197-XXX
Parallel port test warning
1. Make sure
component that is
called out is enabled
and/or connected
2. Re-run test
3. Component that is
called out in warning
statement
4. Component under test
014-198-XXX
Parallel port test aborted
1. If a component is
called out, make sure
it is enabled and/or
connected
2. Flash the system and
re-test
3. Go to “Undetermined
problem” section.
014-199-XXX
Parallel port test failed,
cause unknown
1. Go to “Undetermined
problem” section.
2. Flash the system and
re-test
3. Replace component
under function test.
014-2XX-XXX
014-3XX-XXX
Parallel port failure
1. External parallel
device
2. System board
015-000-XXX
USB port Interface Test
Passed
1. No action
015-001-XXX
USB port Presence
1. Remove USB
Device(s) and re-test
2. System board
015-002-XXX
USB port Timeout
1. Remove USB
Device(s) and re-test
2. System board
015-015-XXX
USB port External Loopback
failure
1. Remove USB
Device(s) and re-test
2. System board
015-027-XXX
USB port
Configuration/Setup error
1. Flash the system
2. System board
015-032-XXX
USB port Device Controller
failure
1. System board
015-034-XXX
USB port buffer allocation
failure
1. Reboot the system
2. Flash the system
3. Run memory test
4. System board
IBM PC Enhanced Diagnostics error codes 9