IBM L2/3 Switch User Manual


 
Chapter 7. Nortel Networks L2/3 GbESM configuration and network integration 121
/* the below is used solely to provide an unused VLAN as PVID for the crossover
/c/l2/vlan 50
ena
def EXT3
/c/l2/stg 1/off
/c/l2/stg 1/clear
/c/l2/stg 1/add 1 10 20 35 46 50
/c/l2/trunk 1
ena
failovr dis
add EXT1
add EXT2
/c/l2/trunk 2
ena
failovr dis
add EXT5
add EXT6
/c/l3/if 10
ena
addr 10.10.0.243
/* addr 10.10.0.244 on GbESM 2
mask 255.255.255.0
broad 10.10.0.255
vlan 10
/c/l3/if 20
ena
addr 10.20.0.243
/* addr 10.20.0.244 on GbESM 2
mask 255.255.255.0
broad 10.20.0.255
vlan 20
/c/l3/if 35
ena
addr 10.35.0.243
/* addr 10.35.0.244 on GbESM 2
mask 255.255.255.0
broad 10.35.0.255
vlan 35
/c/l3/if 46
ena
addr 10.46.0.243
/* addr 10.46.0.244 on GbESM 2
mask 255.255.255.0
broad 10.46.0.255
vlan 46
/c/l3/if 50
ena
addr 10.50.0.243
/* 244 on GbESM 2
mask 255.255.255.0
vlan 50
/c/l3/gw 1
ena
addr 10.35.0.245
/c/l3/gw 2
ena