Super Trusted User Control
Under special circumstances it may be necessary to have a user that should not be checked
through all the SafeNet/400 security routines. Transactions from these users can bypass the
traditional SafeNet/400 security routines; you can choose to simply log them or not log them.
From the Special Jobs Menu select Option 4 – Maintain Super-Users in SafeNet.
You can turn logging on or off for Super Trusted Users by using the CHGSPCSET command
and changing the LOGUSER parameter to *YES or *NO.
Note: This should only be used under conditions when you want NONE of the specified users
transactions to be checked through SafeNet/400 security routines.