350 COG
HS40 processor options
Notes:
1. Up to three additional processors may be installed, providing a maximum of four. All processors must be
identical in type, speed and cache size.
HS40 memory options
Notes:
1. BladeCenter HS40 supports up to 16GB of Chipkill memory via 8 DIMM slots. Removal of standard
memory is required to achieve the supported maximum amount.
2. Due to two-way interleaving, installation of memory options in pairs is required.
HS40 hard disk drive (HDD) storage options
Notes:
1. Each installed HDD will physically prevent installation of one expansion card.
2. Integrated mirroring is supported using these HDDs.
3. The flash disk drives are IDE HDDs and adhere to the same cabling and configuration rules as the
standard IDE HDDs. Both can be installed in the same blade server.
4. Blade servers support attachment of any one expansion unit.
5. Supports two SCSI HDDs. See Blade Server Storage and I/O Expansion section for more information.
SBB
Number
Option
Number
Feature
Code Processor Upgrades
SMP
Support
1
26K4854 13N0656 0312 2.2GHz/400MHz-2MB L3 Cache Xeon Processor MP 5xX
26K4855 13N0655 0313 2.7GHz/400MHz-2MB L3 Cache Xeon Processor MP 6xX
26K4856 13N0654 0314 3.0GHz/400MHz-4MB L3 Cache Xeon Processor MP 7xX
SBB
Number
Option
Number
Feature
Code Memory Description
1, 2
37L3538 33L5038 0507 512MB PC2100 ECC DDR RDIMM
32P9223 33L5040 0509 2GB PC2100 ECC DDR RDIMM
Note: DIMMs are installed in matched pairs using the following population order: DIMM1-A &
DIMM1-B, DIMM2-A & DIMM2-B, DIMM3-A & DIMM3-B, DIMM4-A & DIMM4-B.
SBB
Number
Option
Number
Feature
Code
Description Height
Bays
Supported
Maximum
Quantity
1
IDE HDDs
2
48P7099 25R6906 5213 40GB IDE HDD Slim 1, 2 2
32P0747 32P0727 5215 73.4GB 10K rpm Ultra320 SCSI Hot-swap HDD Slim 3, 4 2
32P0748 32P0728 5216 146.4GB 10K rpm Ultra320 SCSI Hot-swap
HDD
Slim 3, 4 2
Storage Expansion
4
26K4852 26K4847 4203 BladeCenter SCSI Storage Expansion Unit
5
-- -
13N1675 90P3721 4202 BladeCenter PCI Expansion Unit - - -