Appendix F. BladeCenter
®
power module upgrade guidelines 529
Important:
The HS40 blade server occupies two adjacent bays. When you complete the “Power worksheets” on page 532,
enter the power unit value from Table 154 twice, once for each bay that the blade server occupies. If you
install an HS40 blade server in bays 6 and 7, the blade server will use power from both power domain A and
power domain B. In the power worksheets, enter the power unit value twice, once for bay 6 of power domain
A and once for bay 7 of power domain B.
Table 153. HS20 blade server power values
BladeCenter HS20 blade server
IBM power units for the corresponding
number of installed microprocessors
1 microprocessor 2 microprocessors
2.0 GHz/400 MHz (8678-21X) 0.9 1.1
2.4 GHz/400 MHz (8678-41X) 0.9 1.2
2.6 GHz/400 MHz (8678-51X) 1.0 1.2
2.8 GHz/400 MHz (8678-61X) 1.0 1.3
2.4 GHz/533 MHz (8832-9TX) 0.9 1.2
2.8 GHz/533 MHz (8832-21X, 8832-L1X, 8832-LTX) 1.0 1.5
3.06 GHz/533 MHz (8832-31X, 8832-M1X) 1.2 1.6
3.06 GHz/533 MHz (8832-N1X) Does not apply 1.9
3.2 GHz/533 MHz (8832-G1X, 8832-J1X, 8832-GTX) 1.2 1.65
2.8 GHz/800 MHz (8843-L1X and 8843-LTU) 1.05 1.55
2.8 to 3.8 GHz/800 MHz (all 8843 except as listed above) 1.4 2.3
Table 154. HS40 blade server power values
BladeCenter HS40 blade server
(occupies 2 bays)
IBM power units and the corresponding number of installed microprocessors
(power unit value for each bay)
1 microprocessor 2 microprocessors 3 microprocessors 4 microprocessors
2.0 GHz/400 MHz (8839-21X) 0.70 0.90 1.10 1.30
2.2 GHz/400 MHz (8839-51X) 0.70 0.95 1.15 1.40
2.7 GHz/400 MHz (8839-61X,
8839-6TX)
0.75 1.0 1.25 1.55
2.8 GHz/400 MHz (8839-41X) 0.75 1.0 1.30 1.55
3.0 GHz/400 MHz (8839-71X) 0.80 1.1 1.35 1.67