Intel SE7500CW2 Server User Manual


 
34 Intel Server Board SE7500CW2 Product Guide
Console Redirection Submenu
To access this submenu, select Advanced on the menu bar at the top of the screen and then Console
Redirection.
Main
Advanced
Security Power Boot System Exit
I/O Device Configuration
On Board Device
PCI Configuration
Server Menu
Console Redirection
Event Logging
Hardware Monitor
Table 15 lists the options available through the Console Redirection submenu. This submenu
provides additional options to configure the console.
Table 15. Console Redirection Submenu
Feature Choices Description
COM Port Address
Disabled
(default)
On-board
COM A
On-board
COM B
When enabled, console redirection uses the I/O port specified.
All keyboard/mouse and video will be directed to this port. This
setting is designed to be used only under DOS in text mode.
Baud Rate
300
1200
2400
9600
19.2k
(default)
38.4k
57.6K
115.2k
When console redirection is enabled, specifies the baud rate to
be used.
Console Type
PC ANSI
(default)
VT100
Enables the specified console type.
Flow Control
None
XON/XOFF
CTS/RTS
(default)
None disallows flow control.
XON/XOFF is software-based asynchronous flow control.
CTS/RTS is hardware-based flow control.
When EMP is sharing the COM port as console redirection, the
flow control must be set to CTS/RTS.
Console Connection
Direct
(default)
Via modem
Indicates whether the console is connected directly to the
system or whether a modem is used.
Continue C.R. after
POST
Off
(default)
On
Enables console redirection (C.R.) after the operating system
has been loaded.