Configuration Software and Utilities 45
Hardware Monitoring
The Server Board SE7500CW2 has an integrated Winbond Heceta
†
836327HF chip that is
responsible for hardware monitoring. Together, the Winbond Heceta chip and Intel
®
LANDesk
®
Client Manager (LDCM) 6.3 software provide basic server hardware monitoring that alerts a
system administrator if a hardware problem occurs on an Intel Server Board SE7500CW2–based
system. The Intel LDCM software is for use with Windows 2000 Server and Windows 2000
Advanced Server operating systems. Other operating systems supported by the Server Board
SE7500CW2 such as NetWare 6.0 or Red Hat
†
Linux
†
will not be monitored with LDCM.
Table 23 lists the monitored headers and sensors on the Server Board SE7500CW2.
Table 23. Monitored Headers and Sensors
Sensor Type
Item Description
Voltage
CPU1/2 Monitors processor voltage (one CPU power plane)
1.8 V Chipset
VCC3 Monitors VCC3
VCC Monitors VCC
+12 V Monitors +12 V
2.5 V Monitors 2.5 V (for DIMM)
Vbat Battery pin voltage
5 VSB Monitors 5 VSB (5 V stand-by)
Fan Speed
CPU1_FAN Monitors primary processor fan speed
CPU2_FAN Monitors secondary processor fan speed
CHASSIS_FAN Monitors chassis fan speed through chassis fan header
3 only. (Total 4 chassis fans available)
Temperature
CPU2 Monitors primary processor temperature
CPU1 Monitors secondary processor temperature
CHASSIS Monitors chassis ambient temperature
Intel LDCM software and a white paper that provides more information on using Intel LDCM
software are available on the Intel
Server Board SE7500CW2 Resource CD and are also available
for download at the following Web site:
http://www.support.intel.com/support/motherboards/server/SE7500CW2
✏ NOTE
If any system sensors such as CPU1_FAN are not being monitored, please refer to the following
Web site for updates:
http://www.support.intel.com/support/motherboards/server/SE7500CW2