IronPort Systems 4108GL Switch User Manual


 
18-4
Troubleshooting
Browser or Telnet Access Problems
Troubleshooting
Browser or Telnet Access Problems
Cannot access the web browser interface:
Access may be disabled by the Web Agent Enabled parameter in the switch
console. Check the setting on this parameter by selecting:
2. Switch Configuration . . .
1. System Information
The switch may not have the correct IP address, subnet mask or gateway.
Verify by connecting a console to the switchs Console port and selecting:
2. Switch Configuration . . .
5. IP Configuration
Note: If DHCP/Bootp is used to configure the switch, the IP addressing
can be verified by selecting:
1. Status and Counters . . .
2. Switch Management Address Information
also check the DHCP/Bootp server configuration to verify correct IP
addressing.
If you are using DHCP to acquire the IP address for the switch, the IP
address lease time may have expired so that the IP address has changed.
For more information on how to reserve an IP address, refer to the
documentation for the DHCP application that you are using.
If one or more IP-Authorized managers are configured, the switch allows
web browser access only to a device having an authorized IP address. For
more information on IP Authorized managers, see Chapter 10, Using
Authorized IP Managers for Increased Management Security.
Java applets may not be running on the web browser. They are required
for the switch web browser interface to operate correctly. See the online
Help on your web browser for how to run the Java applets.
Wrong OS type or version. See Web Browser Interface Requirements on
page 4-4.
Wrong browser type or version. See Web Browser Interface Require-
ments on page 4-4.