Kodak A-61097 Scanner User Manual


 
2-34 A-61097 May 1997
To program a custom check digit algorithm, use the following sequence of
steps:
1. Select the Attributes parameter for definition.
2. Enter the desired attribute values.
Enter attribute values.
Req’d entry 11 digits.
46231546231
To Change: Enter Value
To Retain: Press Enter
Check Digit = Constant 2 -
[Sum of IA Digits * Attributes] + Constant 1
Divisor
Current ValueParameter
46231546231
00
00
07
Right
No
abcdefghijk
Attributes
Constant 1
Constant 2
Divisor
Left/Right
LUT Status
Lookup Table
Help
Previous Menu
Custom Check Digit Formula
Custom Check Digit Definition
3. Select the Constant1 parameter for definition.
4. Enter a value between 00 – 99.
Enter constant #1.
Req’d entry 2 digits.
00
To Change: Enter Value
To Retain: Press Enter
Check Digit = Constant 2 -
[Sum of IA Digits * Attributes] + Constant 1
Divisor
Current ValueParameter
46231546231
00
00
07
Right
No
abcdefghijk
Attributes
Constant 1
Constant 2
Divisor
Left/Right
LUT Status
Lookup Table
Help
Previous Menu
Custom Check Digit Formula
Custom Check Digit Definition