Kodak A-61097 Scanner User Manual


 
A-61097 May 1997 2-37
13. Select the Lookup Table parameter for definition.
14. Enter the desired lookup table values.
Enter lookup table.
Req’d entry 11 digits.
abcdefghijk
To Change: Enter Value
To Retain: Press Enter
Check Digit = Constant 2 -
[Sum of IA Digits * Attributes] + Constant 1
Divisor
Current ValueParameter
46231546231
00
00
07
Right
No
abcdefghijk
Attributes
Constant 1
Constant 2
Divisor
Left/Right
LUT Status
Lookup Table
Help
Previous Menu
Custom Check Digit Formula
Custom Check Digit Definition
Custom Check Digit Configuration Help
Parameters Explanation
Attributes These are position weights for digit in the IA. A zero-
value attribute causes the associated IA digit to be
excluded from the check digit calculation. Each digit in
the IA is multiplied by its attribute and summed.
Constant 1 A constant in the range 00–99.
Constant 2 A constant in the range 00–99.
Divisor A constant in the range 00–99. Not used if value is
zero.
Left/Right Indicates the location of the check digit in relation to
the decimal point in the calculation results. If left is
specified, the check digit is immediately to the left of
the decimal point and vice versa.
LUT Status If Yes, the final check digit calculated is used as an
index into a lookup table. If No, the lookup table is
ignored.
Lookup Table A table of check digit values.