LaCie Biggest Quadra
User Manual
page 38
Using the Biggest Quadra
5.2.3. Failure and Error Messages■
ese messages will be displayed in the event of a
RAID or disk failure, or an error during a process.
RAID Failure Messages
LCD Display Message Message Cleared When...
RAID Fail
code: 0
e RAID array failed. ere are not
enough disks for the RAID array to
operate.
A disk is re-installed❖
RAID Fail
code: 1 <---->
e RAID array failed. e sequence
of the disks in the array is incorrect.
e current sequence is displayed
within the “<---->” space.
e original disk sequence is
restored
❖
RAID Fail
code: 2
e RAID array failed but all original
disks are existing after restarting the
unit.
e RAID array is recreated.❖
Disk Failure Message
LCD Display Message Message Cleared When...
DISK x Fail
Disk “x” failed. e failed disk is replaced❖
Fan Failure Message
LCD Display Message Message Cleared When...
FAN Fail
xxxx rpm
Fan failure. xxxx rpm = the current
speed of the fan
e failed fan is repaired or replaced❖