LaCie Biggest Quadra
User Manual
page 39
Using the Biggest Quadra
RAID Configuration Failure Message
LCD Display Message Message Cleared When...
RAID Level
Unmatched
e setting of the RAID Level
Switch Selectors does not match the
existing RAID level.
e LaCie Biggest Quadra is shut
down and the RAID Level Switch
Selectors are re-set to their original
RAID level
❖
RAID Fail
code: 1 <---->
e setting of the RAID Level
Switch Selectors does not match the
existing RAID level.
If you intend to initialize a new
RAID array, re-insert four disks
and create a new RAID; or
e LaCie Biggest Quadra is shut
down and the RAID Level Switch
Selectors are re-set to their origi-
nal RAID level
❖
❖
Overheating Error Message
LCD Display Message Message Cleared When...
Over Temperature
53°C
e temperature of the LaCie Biggest
Quadra has reached 53°C.
e temperature drops below 53°C❖
Over Temperature
Disk Shutdown!
e temperature of the LaCie Biggest
Quadra has exceeded 55°C.
Shut down the Biggest Quadra
and wait for the temperature to
drop below 53°C.
❖
5.2.4. RAID and Disk Status Messages■
ese messages will be displayed during one of the
following processes.
Power On
LCD Display Message Message Cleared When...
Biggest Quadra
Boot...
e LaCie Biggest Quadra is being
powered on.
e LaCie Biggest Quadra has com-
pleted its boot process
❖