Settings You Can Change with the User Tools
77
4
Timer Setting
When entering Set Time mode, if a key operator code has been set, you must en-
ter the code (up to 8 digits). ⇒ p.86 “User Code”
❖
❖❖
❖ Auto Off Timer
The machine turns off automatically to conserve energy after a specified
amount of time has past after a job. This function is called "Auto Off".
The machine status after the Auto Off operation is called "Off mode" or "Sleep
mode". For the Auto Off Timer, specify the time to elapse before the Auto Off
function is activated.
The Time can be set from 10 seconds to 240 minutes.
Note
❒ Default: 1 minute
❒ Enter numbers with number keys
❒ Use the [←
←←
←] and [→
→→
→] keys to switch between minutes and seconds.
❒ When in Off or Sleep mode, the machine can be ready for use within 10 sec-
onds.
❒ Auto off may not work while an error is displayed.
❖
❖❖
❖ Panel Off Timer
Set the amount of time the machine waits before switching the panel off after
copying has finished or the last operation is performed.
Note
❒ The default setting is the same time interval as the Auto Off Timer default
setting, so the Panel Off Timer is not used. This setting is only used if the
Auto Off Timer setting is set to a longer interval than the Panel Off Timer
setting.
❒ The warm up time for making a copy from standby mode is three seconds.
❒ The default: 1 minute
❒ Enter a time interval between 10 seconds and 240 minutes with the number
keys.
❒ Press the [←
←←
←] or [→
→→
→] keys to move the cursor between minutes and sec-
onds.
❖
❖❖
❖ System Reset Timer
The System Reset setting is a setting that automatically switches to the screen
for the function set in Function Priority. This happens if no operations are per-
formed or when an interruputed job is cleared. This setting sets the system re-
set interval.
Note
❒ Default: Yes, 60 seconds
❒ The time can be set from 10 to 999 seconds.
RussianC2-EN-sysF1_V4_FM.book Page 77 Thursday, August 23, 2001 11:34 AM