Laser LS8000-3 Computer Accessories User Manual


 
LaserSpeed 8000-3 Instruction Handbook
LaserTrak Software
Part No. 93463 / Drawing No. 0921-01561 Page 118 of 221 Revision A (Sep 2007)
For example, the Quality Factor that indicates the gauge is measuring a poor
light scattering surface when the Quality Factor is relatively constant but
lower then 15. The Gauge will measure accurately under these conditions
as long at the QF stays in the yellow and Green areas.
When the Quality Factor is jumping from 0 to 15 or from the red to the green
area quickly, this typically indicates that the product is moving in and out of
the measuring region of the gauge or there is something interfering with the
Laser beams hitting the surface of the material being measured. The gauge
can not make measurements if the Laser beam does not have a clear path
between the gauge and the surface being measured. This would be indicated
by a Quality Factor equal to zero or in the red zone on the bar graph.
Length Mode Display
The Length Mode Screen Has two modes of operation, the Successive
Reading mode and Final Length mode. Successive Reading mode allows
discrete lengths to be measured and displayed in the form of a Histogram.
The software will acquire the final length measured after the length counter
has remained at the same length for 4 successive User Update Periods. This