$C COM LED Function
$C<CR> Read
Response Format: <N>
$C<N><CR> Set
<N> is either 0 or 1. This setting controls the function of the COM LED on the LS8000-3.
This is a Blue-Orange LED on top of the gauge that indicates communications status. This
value should be set to 0 if your LS8000-3 does not have the Ethernet option installed.
Value COM LED
0 RS-232/RS-422 Traffic
1 Ethernet Status/Traffic
RS-232/RS-422 Traffic
The Orange LED blinks when the LS8000-3 sees activity on the RS-232 or RS-422 receive
lines. This does not indicate that the LS8000-3 understood the message, only that it saw the
voltage change (the baud rate may be incorrect.) This is a diagnostic feature to allow easy
wiring verification.
The Blue LED blinks when the LS8000-3 transmits on either the RS-232 or RS-422 ports. If
the light is continuously blue, then the LS8000-3 is transmitting continuously.
When orange and blue are lit at the same time, the LED is white.
Ethernet Status/Traffic
LED Status Meaning
OFF No Connection
Orange Link
Blue Activity
White Collision