Laser LS8000-3 Computer Accessories User Manual


 
LaserSpeed 8000-3 Instruction Handbook
RS-232/RS-422 Communication
Part No. 93463 / Drawing No. 0921-01561 Page 144 of 221 Revision A (Sep 2007)
The output will clear when the length reaches 200ft, and the Index Pulse triggers. See the
Index Pulse & Length Thresholds
section for timing details.
$H High Speed Pulse Output Configuration
$H<CR> Read
Response Format: <N>
$H<N><CR> Set
<N> is an integer that specifies the function of the High Speed Pulse Output. The various
outputs were described previously in the Index Pulse Output Function description.
Pulse Output Function
Value
Phase A Phase B
0 Default (High Speed Pulse Outputs)
1 System Ready Material Present
2 System Ready Valid
3 System Ready QF Pulse Output
4 System Ready QF Warning Output
5 System Ready Shutter Open
6 System Ready Laser On
7 System Ready Thermostat Output
8 Valid Thermostat Output
9 Pulse Phase A Sync Output
Note: Some of the above outputs were previously described under the Index Pulse Output
Function setting.
Sync Output
Gauge-Gauge Synchronization Output that can be connected between multiple gauges in
order to synchronize measurements. See the Gauge-Gauge Synchronization
section for
details.
L High Speed Pulse Rate
L<CR> Read
Response Format: <N>
L<N><CR> Set