Lathem 24A715 Time Clock User Manual


 
Testing the Bells
Use the AUTO BELL TEST function to turn on all bell relays once per minute at the start
of each minute. This tests the continuity of the bell wiring circuits. This function does not
require a password.
1. If you have entered a password within the last several minutes, deactivate it by fol
-
lowing the instructions under Securing the Setup on page 2-9. If you do not, you will
toggle the clock between 12- and 24-hour format during this procedure.
2. Use the [6]=ENABLE CIRCUITS function to disable any relays that you do not want
to include in the test (see Enabling the Relays on page 2-4).
3. While the clock is displaying the time, press [2][3][5][5][8][7][8] to start the bell test.
While entering this code, ignore anything that displays on the screen.
Note:
After you enter the test command, there may be a delay before the bells sound.
4. When done, re-enter [2][3][5][5][8][7][8] to stop the test.
5. Use the [6]=ENABLE CIRCUITS function to re-enable any relays disabled in step 2.
Setting Daylight Saving Time
If your region observes daylight saving time, use the [7]=DAYLIGHT SAVINGS func-
tion to enter the country code so the master clock will automatically adjust for daylight
saving time. The factory-programmed country code is 08 (United States). See Appendix
A for a list of country codes.
Notes:
If your nation does not appear in the country code list, or if the dates for daylight sav
-
ing in your country have changed, choose code 00 and use the optional Lathem
MasterLink software to program clock adjustments. If your region does not observe
daylight saving time, choose code 00.
Enter the administrative password as shown on page 2-2, then follow these key sequences:
Press Display
[#] SELECT FUNCTION CODE
[7] [7]=DAYLIGHT SAVINGS
[#] ENTER COUNTRY CODE
FOR DAYLIGHT SAVINGS
TIME ADJUSTMENT:
08 (default)
[0]...[9] Enter the country code (see Appendix A).
[#] Press [#] to accept or [*] to cancel.
24A715/24A715M Master Clock Installation Manual