Lathem 24A715 Time Clock User Manual


 
Introduction
This chapter list all functions accessible through the master clock key pad. For detailed
instructions on these functions, see Section 2—Configuration and the Master Clock
User Guide, document 427-07-00047.
Quick Commands
Quick commands are used to display system information for about two seconds. You can
press the quick keys, [*], [1], or [3], when the master is displaying the time and date.
[*] READ STATUS
Any time the master clock is in clock mode (displaying time and date), press [*] to see
the master clock status. See Figure 3-1 and Table 3-1.
24A715/24A715M Master Clock Installation Manual
3-1
Section
Function List
3
02-13-01 VER. 1.06
ID# 065 | BAUD 9600
TIME 12HR | DST 08
CLK1 01 | CLK2 00
Figure 3-1
Status Display
Display Description
Date Displays current programmed date
ID# xxx Terminal ID#
TIME Shows if display is in 12- or 24-hour format
CLK1 | CLK2 Clock types this master clock will synchronize
VER. x.xx Firmware version
BAUD Baud rate for network communications
DST Daylight saving time country code
Table 3-1
READ STATUS Definitions