Understanding the operator panel
Pitch
To specify the font pitch for scalable
monospaced fonts.
0.08...100
(in increments of
0.01 cpi)
Pitch refers to the number of fixed-
space characters in a horizontal inch
of type. You can select a pitch from
0.08 to 100 characters per inch (cpi) in
increments of 0.01 cpi. For
nonscalable monospaced fonts, the
pitch is displayed, but cannot be
changed.
Note: Pitch is only displayed for fixed,
or monospaced, fonts.
10*
Point Size
To change the point size for scalable
typographic fonts.
1...1008
in increments of
0.25 points)
Point size refers to the height of the
characters in the font. One point
equals approximately 1/72 of an inch.
You can select point sizes from 1 to
1008 in increments of 0.25 points.
Note: Point Size is only displayed for
typographic fonts.
12*
Symbol Set
To choose a symbol set for a specified
font name.
10U PC-8*
(country/region-
specific factory
default values)
A symbol set is a set of alphabetic and
numeric characters, punctuation, and
special symbols used when printing
with a selected font. Symbol sets
support the different requirements for
languages or specific applications,
such as math symbols for scientific
text. Only the symbol sets supported
for the selected font name are
displayed.
12U PC-850*
(country/region-
specific factory
default values)
Tray Renumber
To configure your printer to work with printer drivers or applications that use different source
assignments for the paper trays.
Note: See the Technical Reference for more information about assigning source numbers.
1 Select a paper source. Assign Tray <x>
Assign Man Env
Assign Man Paper
2 Select a value. Off* Printer uses factory default paper
source assignments.
0...199 Select a numeric value to assign a
custom value to a paper source.
None Paper source ignores the Select Paper
Feed command.
Other Tray Renumber selections View Factory Def Press
Menu to display the factory
default value assigned to each paper
source.
Restore Defaults Select Yes to return all tray
assignments to factory default values.
Menu item Purpose Values