117
IPDS Timeout = Host Controlled (when using MarkNet S, MarkNet Pro, or
MarkNet XLe)
Note: The printer defaults to Host Controlled when receiving IPDS jobs
on port 9100 or 9102.
If you selected any other IPDS Timeout value, go to IPDS Timeout = 15 seconds
to 10 minutes on page 118.
If you selected the IPDS Timeout value of Host Controlled to allow the host to
directly control ending (disconnecting) a LAN session, follow the steps below to
correct the problem.
1. Adjust the MarkNet S, MarkNet Pro, or MarkNet XLe timeout value to 0
(disabled). See 5 Using the SIMM for IPDS with a MarkNet Adapter or
MarkNet Print Server on page 65 for additional information.
2. Adjust the MarkNet Pro Busy Timeout to (0) disabled. See section 5.3.4
Setting the MarkNet Pro Busy Timeout on page 70 for additional
information.
3. Change the host port setting to 9100, 9102, or 9600. Refer to IPDS Timeout
on page 40 for further information on the selection of ports.
4. Correct the appropriate host timer/timeout value as shown below.
PSF/400 with OS/400 V3R1 or V3R6
WRKAFP2: Inactivity Timer (INACTTMR) *SEC15 or *SEC30
PSF/400 with OS/400 V3R2, V3R7, V4R1, or V4R2
CRTPSFCFG: Release Timer (RLSTMR) *SEC15 or *SEC30
PSF/MVS
PSF Startup Proc: Disconnect Interval (DISCINTV) 15 seconds
PSF/2
TCP/IP Settings: Connect Timeout 30 seconds
Tuning Option: Job Interval Shutdown Timer 30 seconds
PSF/AIX
SMIT Printer Def: Connect Timeout 30 seconds