Lexmark Se 3455 Printer User Manual


 
68
5.2.2 Setting the MarkNet S Job Timeout
The recommended setting for the MarkNet S Job Timeout is 0 (disabled). This allows
the host system "release timer" value and the printer IPDS Timeout value to control
when print jobs from another protocol, interface, server, or host can be started.
You may set the MarkNet S Job Timeout value to a value greater than the host "release
timer" value. Errors are very likely to occur when the printer requires user intervention
and the intervention is not cleared before the timeout occurs.
Setting the MarkNet S Job Timeout smaller than the host "release timer" value or the
printer IPDS Timeout value will result in communication errors after the job has
printed.
From the printer operator panel, do the following:
1. Press Menu> until the NETWORK MENU displays. Press Select.
2. Press Menu> until the NETWORK OPTION 1 displays. Press Select.
(This example assumes the MarkNet S Adapter is installed in option
connector 1.)
3. Press Menu> until you see NETWORK 1 SETUP. Press Select.
4. Press Menu> until you see NETWORK CARD. Press Select.
Here you find the following setting:
Job Timeout 0
(A setting of 0 allows the host system timer or the printer IPDS Timeout value to
control when print jobs from another protocol, interface, server or host can be started.)