92
5.8.2 Printer Sharing Parameters
To enable the printer to start other print jobs from another protocol, interface or server
the following parameters on the PRINTDEV statement have to be coded in the PSF
STARTUP PROC:
MGMTMODE=OUTAVAIL
DISCINTV=15
TIMEOUT=REDRIVE
FAILURE=WCONNECT
IPADDR=157.184.67.102
(address available from your network administrator)
PORTNO=9100
(9100 or 9600 for MarkNet S)
(9100 for Parallel 1 on MarkNet Pro or MarkNet XLe)
(9102 for Parallel 2 on MarkNet Pro or MarkNet XLe)
Refer to 4.3.14 IPDS Timeout on page 40 for further information on the
selection of ports.
The value (15) for DISCINTV specifies the time in seconds after which PSF ends the
printer session when no output is available. The valid range is from 0 to 8160 seconds.
The default value is 0. If DISCINTV=0, the PSF does not end the printer session when
no output is available.
The MarkNet S has a network inactivity timer called Job Timeout. The MarkNet Pro
and the MarkNet XLe adapter has a network inactivity timer called the End-of-Job
Timeout option. We will refer to both as the End-of-Job Timeout. The default is 90
seconds. It is recommended that the End-of-Job Timeout is disabled (set to 0) and the
DISCINTV is set to 15 seconds, if the printer IPDS Timeout value is set to Host
Controlled.