S8 Comma Dial Modifier Time
This register sets the time, in seconds, that the modem must pause when it encounters a comma (,) in the dial
command string.
Range: 0—65
Default: 2
Units: seconds
S10 Automatic Disconnect Delay
This register sets the length of time, in tenths of a second, that the modem waits before hanging up after a loss of
carrier. This allows for a temporary carrier loss without causing the local modem to disconnect.
The actual interval the modem waits before disconnecting is the value in register S10.
Range: 1—254
Default: 20
Units: .1 seconds
S11 DTMF Dialing Speed
This register determines the dialing speed which is prefixed for each country.
Range: 50—150
Default: 95
Units: .001 seconds
S12 Escape Guard Time
This register sets the value (in 20 ms increments) for the required pause after the escape sequence (default 1 s).
Range: 0—255
Default: 50
Units: .02 seconds
S14 General Bit Mapped Options Status
Indicates the status of command options. Only bit 3 and bit 6 are used, read-only.
Bit 3 Result codes (Vn)
0 = Numeric (V0)
1 = Verbose (Vl) (Default)
Bit 6 Pulse dial PPS selection (&Pn)
0 = 10 PPS (&p0, &p1) (Default)
1 = 20 PPS (&p2)
Default: 8 (00001000b)