Lucent Technologies Host-Based Controller Modem AT Modem User Manual


 
Host-Based Controller Modem Data Addendum
AT Command Set June 15, 1998
AT Commands for Homologation Testing and Debugging (continued)
Lucent Technologies Inc. Version 1.0
62
Table 11. The Homologation Testing and Debugging Commands (continued)
Name Description Value Comments
%Txx V.22 1200 originate signaling 90 Set S37 = 5
V.22 1200 answer signaling 91 Set S37 = 5
V.22bis/V.34 2400 originate signaling* 90 Set S37 = 6
V.22bis/V.34 2400 answer signaling* 91 Set S37 = 6
V.32/V.34 4800 originate signaling* 90 Set S37 = 7
V.32/V.34 4800 answer signaling* 91 Set S37 = 7
V.32/V.34 7200 originate signaling* 90 Set S37 = 8
V.32/V.34 7200 answer signaling* 91 Set S37 = 8
V.32bis/V.34 9600 originate signaling* 90 Set S37 = 9
V.32bis/V.34 9600 answer signaling* 91 Set S37 = 9
V.32bis/V.34 12000 originate signaling* 90 Set S37 = 10
V.32bis/V.34 12000 answer signaling* 91 Set S37 = 10
V.32bis /V.3414400 originate signaling* 90 Set S37 = 11
V.32bis/V.34 14400 answer signaling* 91 Set S37 = 11
V.32ter/V.34 16800 originate signaling* 90 Set S37 = 12
V.32ter/V.34 16800 answer signaling* 91 Set S37 = 12
V.32ter/V.34 19200 originate signaling* 90 Set S37 = 13
V.32ter/V.34 19200 answer signaling* 91 Set S37 = 13
V.21 Channel 2 mark symbol 91 Set S37 = 3
V.21 Channel 2 space symbol 93 Set S37 = 3
V.27 2400 signaling 76
V.27 4800 signaling 77
V.29 7200 signaling 78
V.29 9600 signaling 79
V.17 12000 signaling 80
V.17 14400 signaling 81
Off-Hook 82 This puts the modem in off-hook state.
V.34 21600 originate signaling 90 Set S37 = 14
V.34 21600 answer signaling 91 Set S37 = 14
V.34 24000 originate signaling 90 Set S37 = 15
V.34 24000 answer signaling 91 Set S37 = 15
V.34 26400 originate signaling 90 Set S37 = 16
V.34 26400 answer signaling 91 Set S37 = 16
V.34 28800 originate signaling 90 Set S37 = 17
V.34 28800 answer signaling 91 Set S37 = 17
V.34bis 31200 originate signaling 90 Set S37 = 18
V.34bis 31200 answer signaling 91 Set S37 = 18
V.34bis 33600 originate signaling 90 Set S37 = 19
V.34bis 33600 answer signaling 91 Set S37 = 19
The default is V.34 with register S28 = 1. To disable, set S28 = 0.
The following example shows how to use the V.22bis 2400 originate signaling homologation test command:
S28 = 0
S37 = 6
AT%T90