McDATA 8832 Switch User Manual


 
IBM BladeCenter Deployment Guide
Figure 8 Storage Connection Diagram
2.4.2 Disabling ports on the QLogic switch
Here are the steps necessary to disable ports on the QLogic switch. This can be done either via a telnet
session or a browser session.
2.4.2.1 Using Telnet
1. Start a telnet session with the IP address of the QLogic Switch Module.
2. After logging in, enter the command ”show port” to view the current status of the ports.
Version 3.0, 3/10/2006 http://w3-03.ibm.com/support/techdocs/atsmastr.nsf/WebIndex/WP100564
13
Figure 9 Port Status Online
Admin Operational Login Config Running Link Link
Port State State Status Type Type State Speed
---- ----- ----------- ------ ------ ------- ----- -----
Ext1:0 Online Online LoggedIn GL F Active 1Gb/s
Ext2:15 Online Offline NotLoggedIn GL Unknown Inactive Auto
Bay1 Online Online LoggedIn F F Active 2Gb/s
Bay2 Online Offline NotLoggedIn F Unknown Inactive 2Gb/s
Bay3 Online Offline NotLoggedIn F Unknown Inactive 2Gb/s
Bay4 Online Online LoggedIn F F Active 2Gb/s
Bay5 Online Offline NotLoggedIn F Unknown Inactive 2Gb/s
Bay6 Online Offline NotLoggedIn F Unknown Inactive 2Gb/s
Bay7 Online Offline NotLoggedIn F Unknown Inactive 2Gb/s
Bay8 Online Offline NotLoggedIn F Unknown Inactive 2Gb/s
Bay9 Online Offline NotLoggedIn F Unknown Inactive 2Gb/s
Bay10 Online Offline NotLoggedIn F Unknown Inactive 2Gb/s
Bay11 Online Offline NotLoggedIn F Unknown Inactive 2Gb/s
Bay12 Online Offline NotLoggedIn F Unknown Inactive 2Gb/s
Bay13 Online Offline NotLoggedIn F Unknown Inactive 2Gb/s
Bay14 Online Offline NotLoggedIn F Unknown Inactive 2Gb/s
The BladeCenter Deployment Guide is intended as a personal productivity tool. It is not intended to be comprehensive and is provided for
guidance only, on an 'as is basis' without warranty of any kind. Please be aware that its contents have not been certified by IBM.