Microtest TSB-67 - 568A Annex E Scanner User Manual


 
Page 55
High Voltage Input/Protection
The test interface withstands input hazard conditions that arise from normal telephone
interfaces (48 VDC at less than 80 mA) or 24 VAC power used to power many telephone
keysets.
2-Way Injector+/2-Way Injector
Environmental, Physical Characteristics, User Interface, Measurement Port
Refer to specifications for
PentaScanner+
/
PentaScanner
/
PentaScanner
Cable Admin
LED Displays
Pass Indicator (GREEN) for test result
Fail Indicator (RED) for test result
Status Indicator (GREEN) for 2-Way Injector status
Charging Indicator (RED) for battery status
Hazard Indicator (RED) for high voltage input protection warning
Audible Feedback
Programmable tone generation through a piezo-electric transducer to signal test is complete or
overvoltage conditions
Rechargeable Battery
Removable, rechargeable Nickel Cadmium (Ni-Cd)
Capacity: 1200 mAh
Battery Life: 8+ hours daily operation
Charging Time: 14 hours (via AC Adapter)
2-3 hours (via Battery Charger)
High Voltage Input/Protection
The test interface withstands input hazard conditions that arise from normal telephone
interfaces (48 VDC at less that 80 mA) or 24 VAC power used to power many telephone
keysets.
FLASH Memory
128K FLASH memory is provided to allow for software updates in the field
Power Control
AC Adapter or Battery
Auto-shutoff when operating on battery
Power on under Scanner control
Injector End Termination to Support Scanner Measurements
OPEN (during Impedance, Capacitance, and Length measurements and during
Communication)
SHORT (during Loop Resistance measurements)
100 Ohm Termination (during NEXT measurements)
Swept signal injections during Autotest