Moen 200-0564 Scanner User Manual


 
2. While holding down CLEAR, insert a pointed object, such as a
straightened paper clip, into the reset opening on the side of the
scanner. Then gently press and release the reset button inside the
opening.
Note:
You must release the reset button before you release CLEAR.
Otherwise, the memory might not clear.
3. When the display reappears, release CLEAR.
(br/km-03/06/1997)
Handheld Scanner
(200-0564) Specifications Faxback Doc. # 38260
Frequency Coverage
Ham.............................................29-30 MHz (in 5 kHz steps)
VHF Lo..........................................30-50 MHz (in 5 kHz steps)
Ham.............................................50-54 MHz (in 5 kHz steps)
Aircraft..................................108-136.975 MHz (in 25 kHz steps
Government....................................137-144 Mhz (in 5 kHz steps)
Ham...........................................144-148 MHz (in 5 kHz steps)
VHF Hi........................................148-174 MHz (in 5 kHz steps)
Ham/Government.............................380-450 MHz (in 12.5 kHz steps)
UHF Lo.....................................450-470 MHz (in 12.5 kHz steps)
UHF T......................................470-512 MHz (in 12.5 kHz steps)
UHF Hi.....................................806-824 MHz (in 12.5 kHz steps)
849-869 MHz (in 12.5 kHz steps)
894-960 MHz (in 12.5 kHz steps)
Channels of Operation........................................400 channels,
40 monitor memories, 10 priority channels
Sensitivity (20 dB S/N):
FM
29-54 MHz.........................................................1 uV
108-136.975 MHz...................................................1 uV
137-174 MHz.......................................................1 uV