Moen 200-0564 Scanner User Manual


 
380-512 MHz.......................................................1 uV
806-960 MHz.......................................................2 uV
AM
29-54 MHz.........................................................2 uV
108-136.975 MHz...................................................2 uV
137-174 MHz.......................................................2 uV
380-512 MHz.......................................................2 uV
806-960 MHz.......................................................4 uV
Selectivity:
-6 dB..........................................................+/- kHz
-50 dB........................................................+/20 kHz
Spurious Rejection...................................40 dB at 154 MHz (FM)
Scanning Rate.....................................Up to 25 channels/second
Search Rate..........................................Up to 50 steps/second
Delay Time.......................................................2 seconds
Intermediate Frequencies (IF):
1st..........................................................257.5 MHz
2nd...........................................................21.4 MHz
3rd............................................................455 kHz
IF Rejection:
257.5 MHz @ 154 MHz..............................................50 dB
21.4 MHz @ 154 MHz..............................................100 dB
Squelch Sensitivity:
Threshold (FM and AM).............................................1 uV
Tight (FM).......................................................25 dB
Tight (AM).......................................................20 dB
Antenna Impedance..................................................50 Ohms
Audio Output Power (10% THD)........................................180 mW