Multi-Tech Systems DT102/xx Fax Machine User Manual


 
105
Chapter 7 - Troubleshooting
7.10Data Port Configuration
Table 7-10. Data Port Configuration
Step Procedure
1 Toggle DIP switch position 3 to the down (closed) position to enable the command port.
2 Connect a terminal or PC running communications software to the DATA/COMMAND
connector on the back panel of the DataTalker.
Note: Any cables connected to the computer should be shielded to reduce interference.
3 Apply power to the DataTalker.
4 Apply power to the terminal or PC. Run the PC’s communications software in terminal mode
and press ENTER twice to establish communications with the DataTalker. The Main Menu
appears:
Main Menu
1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP
Selection : _
5 Enter 1 and press ENTER. The Configurations menu is displayed:
Configurations
1 - Data Port Configuration
2 - Voice/Fax Channel(s) Configuration
3 - Composite Link Configuration
4 - Factory Default Configuration Options
5 - Configure Remote Unit
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
6 Enter 1 and press ENTER to display the Data Port Configuration menu.
Data Port Configuration
1 - Async/Sync: Async
2 - Speed: 19200
3 - Word Length: 8
4 - Stop Bits: 1
5 - Parity: None
6 - Flow Control: CTS
7 - Enq/Ack Flow Control: Off
8 - Echo: Off
9 - Pacing: Off
10 - EIA Pass Through: Off
11 - Pass Xon: Off
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _