Multi-Tech Systems DT102/xx Fax Machine User Manual


 
63
Chapter 5 - Installation
Voice/Fax Channel
If the voice/fax channel is not communicating with the remote site or the remote site cannot
communicate with you, check the following items:
• The channel configuration does not match how the channel is cabled. Verify that the
channel configuration and cabling match.
• The remote DataTalker does not match the remote interface type. See Chapter 4.
• The telephone or fax machine is connected to the wrong connector. Verify the cable
connection.
• The telephone must be an analog phone. Check with your telephone people to ensure that
the telephone is not a digital instrument.
• The line connection to your local telephone switch is a digital line. Have your telephone
people provide an analog line.
This completes the installation of your DataTalker.