6.4 Reset Options
The Reset Options menu allows you to reset the unit, the data and voice/fax channels, each
voice/fax channel, or just the data channel.
Reset Options
1 - Reset Unit
2 - Reset Data and Voice/Fax Channels
3 - Reset Voice/Fax Channel 1
4 - Reset Voice/Fax Channel 2
5 - Reset Data Channel
M - Main Menu
P - Previous Menu
Selection : _
To reset the unit, enter 1 and press ENTER. To reset the data and voice/fax channels, 2 and
press ENTER. To reset either voice/fax channel, enter the appropriate number and press
ENTER. To reset just the data channel, enter 5 and press ENTER. To return to the previous
menu, enter P and press ENTER. To return to the Main Menu, enter M and press ENTER.
6.5 Diagnostic Tests
The Diagnostic menu allows you to run three different tests, display the DIP switch settings, and
return to the previous menu or the Main Menu. The loop test option produces a submenu that
allows either a data loopback function or voice loopback function. (Tests for the ISDN terminal
adapter are described in the ISDN Terminal Adapter Owner’s Manual.)
Diagnostics
1 - Loop Test
2 - Memory Test
3 - Watch Dog Test
4 - Dip Switch Definitions and Settings
5 - Product and Firmware ID
M - Main Menu
P - Previous Menu
Selection : _
The Loop Test option checks the operation of the local unit. When this option is selected, a loop
test menu is displayed. See “Loop Tests” in section 6.5.1.
The Memory Test option checks the on-board memory. When this option is selected, a warning
message is displayed. The memory test will destroy all stored configurations. See “Diagnostic
Testing” in section 7.12.
The Watch Dog Test option verifies the watch dog timer circuitry. A message is displayed that
the test will reset the unit. See “Diagnostic Testing” in section 7.12.
The Dip Switch Definitions and Settings option displays a screen that shows the definition of
each switch and its current setting.
The Product and Firmware ID option defines the product and its current firmware release
version.