50
DataTalker Owner’s Manual
9 Configure the data port to meet the conditions of your installation by selecting option
numbers from the menus. Refer to Chapter 6 for a description of the Data Port Configuration
menu options.
For example, if you are setting up the data port as a sync data channel, enter number 1 and
press ENTER. The Data Port Async/Sync menu appears:
Data Port Async/Sync
1 - Async
2 - Sync
P - Previous Menu
Selection : _
Select option 2 to select the sync mode of operation, and the data port configuration menu
reappears.
10 When all options for the data port configuration have been set, enter the letter S and press
ENTER to store all configurations. Then enter the letter P and press ENTER to return to the
configuration menu.
Voice/Fax Channel Configuration
11 If the voice/fax channels of both the local and remote DataTalkers are being connected to
telephone sets, i.e., both local and remote interfaces are FXS type, then you can skip the
Voice/Fax Channel Configuration menu. Proceed to the Composite Link Configuration menu.
If either the local or the remote voice/fax channel is being connected to a PBX, then you must
configure the voice/fax channel. Enter 2 and press ENTER for the Voice/Fax Channel
Configuration menu.
If two voice/fax channels are installed in the DataTalker, a voice/fax channel configuration
menu appears that allows you to configure either channel. Select the voice/fax channel that
needs to be configured.
Voice/Fax Channel 1 Configuration
1 - Destination Channel : 1
2 - Digitizing Rate : 9600
3 - Output Level Atten. : 12
4 - Input Level Gain : 03
5 - Silence Suppression : Off
6 - Local Interface Type : FXS
7 - Ground/Loop Start (FXS) : Loop
8 - 2 or 4 Wire (E&M) : N/A
9 - Dialtone/Wink (E&M) : N/A
10 - Wink Timer (E&M) : N/A
11 - Remote Interface Type : FXS
12 - Ground/Loop Start (FXS) : Loop
13 - 2 or 4 Wire (E&M) : N/A
14 - Dialtone/Wink (E&M) : N/A
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _