Multi-Tech Systems DT102/xx Fax Machine User Manual


 
144
DataTalker Owner’s Manual
Listing On-Line Diagnostics L8
The L8 command displays the current on-line CONNECT status status of the MMH2834. This
display can be printed and used as a modem status report or as diagnostic information (such as
when calling Tech Support).This report is given only when on-line. To activate this command first
type +++AT<CR> (on-line escape command while maintaining command mode), then type ATL8.
What then displays on your monitor is your modem's current on-line condition (e.g., Link Type,
Line Speed, Serial Speed, Type of Error Correction/Data Compression, Number of past
Retrains,etc.).
An example of L8 listing is shown below:
ATL8
****** ONLINE DIAGNOSTICS ******
LINK TYPE V.34
LINE SPEED 28800
SERIAL SPEED 115200
ERROR CNTRL/COMPRESS LAPM COMPRESSED
FALL BACK/FORWARD LOCALLY ENABLED
LINE TYPE DIAL UP
DATA FORMAT ASYNCHRONOUS
LINE QUALITY 0010=EXCELLENT, 8=FAIR, 16=BAD
RECV. SIGNAL LEVEL -016.5 dBM
TRANS SIGNAL LEVEL -013 dBM
NUMBER OF RETRAINS 000
ROUND TRIP DELAY 00ms (MEANINGFUL IN V32 MODE ONLY)