Sample Configurations
Sample RAID Configuration
NCR S10 Desktop Server User Guide C-19
2.
Select SCSI Disk Utilities. Observe that the
information that displays for the 2 GB disk drive
and the CD-ROM drive is correct. If a low-level
format on the 2 GB disk drive is needed, perform it
now. It is usually not needed.
3.
Select Configure/View Host Adapter Settings and
set the parameters as follows:
SCSI Bus Interface Definitions
Host Adapter SCSI ID [7]
SCSI Parity Checking [Enabled]
Host Adapter SCSI Term [Low ON/High ON]
Boot Device Options:
Boot Target ID [0]
Boot LUN Number [0]
4.
Select SCSI Device Configuration and set the
parameters as follows:
SCSI Device ID (tab to desired device)
Initiate Sync Negotiation [yes]
Maximum Sync Transfer Rate [20]
Enable Disconnection [yes]
Initiate Wide Negotiation [yes]
Send Start Unit Command [yes]
5. Press [Enter] to return to previous menu.
6. Select Advanced Configuration Options and set the
parameters as follows:
Host Adapter BIOS (Config Util...) [Enabled]
Support Removable Disks... [Boot Only]