Program 81 : Basic Hardware Setup for Trunk
81-01 : COIU Initial Data Setup
Aspire ISDN PRI Manual 119
Program 81 : Basic Hardware Setup for Trunk
81-01 : COIU Initial Data Setup
Description
Use Program 81-01 : COIU Initial Data Setup to dene the various basic timers for COIU PCBs.
Input Data
Level:
Aspire S Aspire
MF •Available. Available.
Item
No.
Item Input Data Default
01 Companding Method Type 0 = u-law
1 = A-law
0 (u-law)
02 Loop Current Detection Time 1-255 (8-2040mS) 75 (600ms)
03 Clear Signal (Open Loop) Detection Time 1-255 (8-2040mS) 90 (720ms)
04 Ringing Signal Detection Minimum Time 1-255 (8-2040mS) 13 (104ms)
05 Single Ringing Detection Minimum Time 0-255 (0,8-2040mS) 82 (656ms)
06 Double Ringing Detection Minimum off Time 0-255 (0,8-2040mS) 13 (104ms)
07 Double Ringing Detection Maximum off Time 0-255 (0,8-2040mS) 50 (400ms)
08 Ringing Signal Not Detected Minimum 1-255 (8-2040mS) 88 (704ms)
09 Abandoned Call Detection Timer 1-255 (64-16320mS) 94 (6016ms)
10 Continuous Ringing Minimum Time 0-255 (0,8-2040mS) 38 (304ms)
11 Continuous Ringing Maximum Time 0-255 (0,8-2040mS) 88 (704ms)
12 AC Impedance Timer 1-255 (64-16320mS) 4 (256ms)
13 Grounding Time 1-255 (4-1020mS) 9 (36ms)
14 Flash (Hooking 1)
This sets the ash (Hooking 1) duration for analog trunk calls. See Pro-
gram 14-02-04.
1-255 (16-4080mS) 50 (800ms)
15 Flash (Hooking 2)
This sets the ash (Hooking 2) duration for analog trunk calls. See Pro-
gram 14-02-04.
1-255 (16-4080mS) 156 (2496ms)
16 Pause Time 1-255 (16-4080mS) 16 (1024ms)
17 PFT Idle Detection Time 1-255 (64-16320mS) 47 (3008ms)
18 Grounding Start Time 1-255 (8-2040mS) 6 (48ms)
19 Grounding Start Give-Up Time 1-255 (64-16320mS) 47 (3008ms)
20 Loop Reverse Detect Minimum Time 1-255 (8-2040mS) 13 (104ms)
21 Loop Reverse Detect Maximum Time 1-255 (8-2040mS) 107 (856ms)