NEC ISDN-PRI Printer Accessories User Manual


 
Program 10 : System Conguration Setup
10-03 : PCB Setup
44 Aspire ISDN PRI Manual
Note 1. The start port number of a PRI line is displayed. Thirty logic ports are automatically
assigned to a PRI line.
Note 2. Each timer value of Layer3 is set up for each type in Program 81-06 (T-Bus) and Pro-
gram 82-06 (S-Bus).
Conditions
(A.) When changing a dened terminal type, rst set the type to ‘0’ and then plug the new device in
to have the system automatically dene it or redene the type manually.
(B.) The system must have a PCB installed in order to view/change the options for that type of
PCB.
Feature Cross Reference
None
09 Dial Information Element
(Only for Overlap Sending Mode)
0 = Keypad Facility
1 = Called Party Number
0
10 Master/Slave System (Network Mode
only)
0 = Slave System
1 = Master System
0
11 Networking System Number (Net-
work Mode only)
0-50 0
12 short / long-haul 0 = short-haul
1 = long-haul
0
13 Loss-Of-Signal detection limit In short-haul mode
0 = 0.91V
1 = 0.74V
2 = 0.59V
3 = 0.42V
4 = 0.32V
5 = 0.21V
6 = 0.16V
7 = 0.10V
In long-haul mode
0 = 1.70V
1 = 0.84V
2 = 0.84V
3 = 0.45V
4 = 0.45V
5 = 0.20V
6 = 0.10V
7 = not dened
0
14 Service Protocol for S-Point 0 = Keypad Facility
1 = Specied Protocol for Aspire System
0
Item
No.
Item Input Data Default