NEC ISDN-PRI Printer Accessories User Manual


 
Program 81 : Basic Hardware Setup for Trunk
81-01 : COIU Initial Data Setup
120 Aspire ISDN PRI Manual
Conditions
None
Feature Cross Reference
Central Ofce Calls, Placing
22 Loop Disconnect Detect Minimum Time 1-255 (8-2040mS) 50 (400ms)
23 Loop Disconnect Detect Maximum Time 1-255 (8-2040mS) 80 (640ms)
24 On Hook Normal Detect Time 1-255 (8-2040mS) 3 (24ms)
25 On Hook Reverse Detect Time 1-255 (8-2040mS) 2 (16ms)
26 On Hook Disconnect Detect Time 1-255 (16-4080mS) 188 (3008ms)
27 Pulse Dial Break Time (10pps) 1-255 (4-1020mS) 8 (32ms)
28 Pulse Dial Make Time (10pps) 1-255 (4-1020mS) 4 (16ms)
29 Inter-Digit Time (10pps) 1-255 (32-8160mS) 19 (608ms)
30 Pulse Dial Break Time (20pps) 1-255 (4-1020mS) 4 (16ms)
31 Pulse Dial Make Time (20pps) 1-255 (4-1020mS) 2 (8ms)
32 Inter-Digit Time (20pps) 1-255 (32-8160mS) 16 (512ms)
33 Charging Pulse Minimum Duration Time 1-255 (8-2040mS) 9 (72ms)
34 Charging Pulse Minimum Period Time 1-255 (8-2040mS) 29 (232ms)
35 Charging Pulse Minimum Interval Time 1-255 (8-2040mS) 6 (48ms)
Item
No.
Item Input Data Default