Architecture Property Management System - Communication Interface
Timers
The following timers are used to maintain data transmission:
Sender Timer
Upon sending a start sequence, message text or query, this timer begins counting
and stops counting upon receiving a valid answer control code. This timer is set to
one (1) second. If a timeout occurs after the transmission of a start sequence, a start
sequence will be resent up to 15 times. If a timeout occurs during the transmission
of a message text or query, a query is sent up to 32 times.
Receiver Timer
Upon transmission of a positive acknowledgment for a start sequence or a message
text, this timer begins counting and stops counting upon receiving a message text
or an end code. This timer is set to 35 seconds. If a timeout occurs, the sender loses
send rights.
Cabling
Considerations
When the PMS is connected to the NEAX through a modem, the cables should just
be straight through cables. There should be no crossing.
When the PMS is directly connected to the NEAX, use the following pin
assignments:
Figure 2-4 Direct Connection Pin Assignments
Bisynchronous (BSC) Transmission
Line Control
Characteristics
The characteristics of the signals transmitted across the communications link are as
follows:
1FG
SD
RD
RS
CS
DR
SG
CD
ER
2
3
4
5
6
7
8
20
FG
SD
RD
RS
CS
DR
SG
CD
ER
1
2
3
4
5
6
7
8
20
Pin No. Signal Cable
Signal Pin No.
NEAX PMS