Page 36 NDA-30115 Revision 1.0
Message Formats Property Management System - Communication Interface
Room Answer
Figure 4-5 Room Answer (General)
Message fields are:
• FC -- Function Codes that use this message format are: (FTC-FN)
• 51-8 -- Negative Answer (Model 90)
• 51-9 -- Positive Answer (Model 90)
• Extension -- Extension number. If the extension number is less than six digits,
left justify the number and fill the remaining bytes with space (20H) characters.
• LEN -- Line Equipment Number.
• Request -- Room Status Change Request. The possible values are:
• 0 -- Room Status is not to be changed.
• 1 -- Room Status is to be changed.
• Room Status -- Room status. This flag is used in conjunction with the cleaning
status flag to determine the status of the room.
• Cleaning Status -- Cleaning status. The possible combinations with room status
are listed below:
LEN
** Multiple Function Codes use this message. See below.
Request
Room
Status
Cleaning
Status
‘5’‘1’‘2’‘0’ ** Extension
01234 6 89 15 21
STXSAUAEIFTCMSCFC661
02H ‘1’‘!’‘L’
03H xx
ETX BCC
22 23 24 25
11
2
2
0
0
0
0
0
1
0
1
2
4
Stay, Departure Day
Stay, Departure Day, Cleaning in progress
Out (Checked Out)
Out, Cleaning in progress
Out, Cleaning ended
Out of Order (Cannot sell)
Room
0
1
1
Clean
3
0
1
Status of the Room
Vacant (Ready to sell)
Stay (Occupied)
Stay, Cleaning in progress
1
1
2
3
Stay, Cleaning ended
Stay, Inspected