NEC NDA-30115-001 Network Card User Manual


 
NDA-30115 Revision 1.0 Page 83
Property Management System - Communication Interface Message Formats
Direct Data Entry
Figure 4-55 Direct Data Entry
Extension -- Extension number. If the extension number is less than six digits,
left justify the number and fill the remaining bytes with space (20H) characters.
Numeric Input -- Numeric information entered after the special access code.
LEN -- Line Equipment Number of the extension.
Direct Data Entry
Answer
Figure 4-56 Direct Data Entry Answer
The message fields are:
FC -- Function Codes that use this message format are: (FTC-FC)
59-8 -- Direct Data Entry Negative Answer
59-9 -- Direct Data Entry Positive Answer
Extension -- Extension number. If the extension number is less than six digits,
left justify the number and fill the remaining bytes with space (20H) characters.
LEN -- Line Equipment Number of the extension.
5’‘9’‘4’‘7’‘1 Extension
Numeric
Input
01234 6 89 15
STX SA UA EI FTC MSC FC 6 30
02H 1’‘!’‘L
xx
ETX BCC6
45 51 52
03HLEN
5’‘9’‘1’‘7 ** Extension LEN
01234 6 89 15 2122
STX SA UA EI FTC MSC FC 6 6
02H 1’‘!’‘L 03H xx
ETX BCC
** Multiple Function Codes use this message. See below.