NDA-30115 Revision 1.0 Page 55
Property Management System - Communication Interface Message Formats
Wake Up
Execution Result
Figure 4-27 Wake Up Execution Result
Message fields are:
• Extension -- Extension number. If the extension number is less than six digits,
left justify the number and fill the remaining bytes with space (20H) characters.
• Time -- Time for which a wake up was set. Format used is HHMM using
military time.
• Result -- Code for the result of the wake up call. Possible values are:
• 1 -- Answer.
• 2 -- Busy.
• 3 -- No answer.
• 4 -- Block.
• 5 -- Call Termination to Attendant Console.
01234 6 89 15
STX SA UA EI FTC MSC FC 6 4
02H ‘1’‘!’‘L’
03H xx
ETX BCC1
19 20 21
‘1’‘9’‘1’‘6’‘3’ Extension Time
Result