NEC NDA-30115-001 Network Card User Manual


 
NDA-30115 Revision 1.0 Page 73
Property Management System - Communication Interface Message Formats
Room Image Set 1
Figure 4-47 Room Image Set 1
The message fields are:
FC -- Function Codes that use this message format are: (FTC-FC)
17-1 -- Room Image Set 1 (Normal Request from PMS)
17-2 -- Room Image Set 1 (Normal Answer from NEAX)
17-3 -- Room Image Set 1 (Recovery Request from PMS)
17-4 -- Room Image Set 1 (Recovery Answer from NEAX)
Extension -- Extension number. If the extension number is less than six digits,
left justify the number and fill the remaining bytes with space (20H) characters.
Vacancy -- Vacancy/Occupancy flag. The possible values are:
0 -- Vacant.
1 -- Occupied.
Status - Message Waiting status. The possible values are:
0 -- Message Waiting Lamp is off.
1 -- Message Waiting Lamp is on.
Code -- Restriction code for this extension. The possible codes are:
0 -- Do Not Disturb and Room Cut-Off are cancelled.
1 -- Room Cut-Off is set, Do Not Disturb is cancelled.
5 -- Do Not Disturb is set, Room Cut-Off is cancelled.
6 -- Do Not Disturb and Room Cut-Off are set.
Blank -- Field contains 14 space (20H) characters.
1’‘7’‘2’‘8 ** Extension Vacancy
Status Code Blank
** Multiple Function Codes use this message. See below.
01234 6 89 15
STX SA UA EI FTC MSC FC 6 1
02H 1’‘!’‘L
03H xx
ETX BCC1114