Page 58 NDA-30115 Revision 1.0
Message Formats Property Management System - Communication Interface
Group
Announcement
Setting (NEAX)
Figure 4-30 Group Announcement Setting (NEAX)
Message fields are:
• Group ID -- Group number to set. If the group number is less than six digits, left
justify the number and fill the remaining bytes with space (20H) characters.
• Time -- Time for which a group announcement call is set. Format used is
HHMM using military time.
• Source -- Code for the source of the group announcement setting. Possible
values are:
• 1 -- Guest Extension.
• 2 -- Attendant.
• 3 -- Administration Extension.
• 4 -- Property Management System.
• Type -- Code for the type of announcement. The values for the code are
determined by the site, and therefore cannot be listed here.
Type
01234 6 89 15
STX SA UA EI FTC MSC FC 6 4
02H ‘1’‘!’‘L’
03H xx
ETX BCC
11
19 20 21 22
‘1’‘9’‘1’‘7’‘6’ Group ID Time
Source