NEC NDA-30115-001 Network Card User Manual


 
NDA-30115 Revision 1.0 Page 45
Property Management System - Communication Interface Message Formats
Check Out
Outgoing Call
Report
Figure 4-15 Check Out Outgoing Call Report
The only message field is the extension number who is being checked out. If
the extension number is less than six digits, left justify the number and fill
the remaining bytes with space (20H) characters.
Check Out
Message Waiting
Report
Figure 4-16 Check Out
Message fields are:
Extension -- Extension number. If the extension number is less than six digits,
left justify the number and fill the remaining bytes with space (20H) characters.
Status -- Message Waiting Lamp status. The status values are:
0 -- No messages waiting.
1 -- Message waiting set by the NEAX.
4 -- Message waiting set by the PMS.
5 -- Message waiting set by both the PMS and NEAX.
Blank -- Field contains one space (20H) character.
C1’‘6’‘1’‘1 Extension
01234 6 89 1516
STX SA UA EI FTC MSC FC 6
02H 1’‘!’‘L 03H xx
ETX BCC
1’‘6’‘1’‘3
01234 6 89 15
STX SA UA EI FTC MSC FC 6 1
02H 1’‘!’‘L
03H xx
ETX BCC
1
16 17 18
Blank
D Extension Status