NDA-30115 Revision 1.0 Page 35
Property Management System - Communication Interface Message Formats
Guest Room
Figure 4-4 Guest Room (General)
Message fields are:
• FC -- Function Codes that use this message format are: (FTC-FC)
• 51-1 -- Guest Room 1 (Model 90)
• 51-2 -- Guest Room 2 (Model 90)
• 51-3 -- Guest Room 3 (Model 90)
• 51-4 -- Guest Room 4 (Model 90)
• 51-5 -- Guest Room 5 (Model 90)
• 51-6 -- Guest Room 6 (Model 90)
• 51-7 -- Guest Room 7 (Model 90)
Note:
This message was not previously defined in NEAX2400 IMS Hotel System PMS
Interface Specification.
• Extension -- Extension number. If the extension number is less than six digits,
left justify the number and fill the remaining bytes with space (20H) characters.
• Maid -- Identification number of the maid. If the maid identification number is
less than six digits, left justify the number and fill the remaining bytes with
space (20H) characters.
• LEN -- Line Equipment Number.
** Multiple Function Codes use this message. See below.
LEN
‘5’‘1’‘2’‘3’ ** Extension Maid
01234 6 89 15
STX SA UA EI FTC MSC FC 6 6
02H ‘1’‘!’‘L’
03H xx
ETX BCC
21 27 28
6