Nlynx MinIT6000 Network Router User Manual


 
Solution
1. Assuming you know the name of the subsystem you can easily check this by typing
"WRKACTJOB" and then the <Enter> key.
2. Look for the subsystem; page down, if necessary. If you don't see it, type "STRSBS
ZZZ" (where ZZZ equals the name of your subsystem) and then the <Enter> key.
Note: To start a subsystem, the user must have job control (*JOBCTL) special authority.
Possible Cause 4.2.5
The network route is not up.
Solution
Make certain that the route(s) is/are up and running.
1. On the AS/400 command line, type CFGTCP followed by the <enter> key.
2. Select the option Work with TCP/IP Interfaces, by typing a 1 and then <enter>.
3. Hit the <F11> key to Display Interface Status.
4. If it is "Inactive", use option 9 to start it.
5. If it reads "Starting", give it about a minute or so and then hit "F5" to refresh the display.
If anything else other than "Inactive" or "Starting" appears it's time to get the AS/400
administrator involved and if he or she is already involved then it's time to call IBM, or
your AS/400 Consultant.
Possible Cause 4.2.6
The Ethernet standard is not set to *ALL or the line speed setting is not correct.
Solution
If you're connecting the AS/400 via an Ethernet line there is a parameter, which may
prevent the MinIT 6000 from ‘talking’ to the AS/400. This can be checked by:
1. On the AS/400 command line, type WRKCFGSTS *LIN followed by the <enter>
key.
2. Once you locate the line you are trying to connect to, select the option Work with
Description, by typing a 8 and then <enter>.
3. Type the 5 and then <enter> to bring up the Display.
4. Make sure that Ethernet standard is set to *ALL and that the correct line speed is
displayed.
5. The line speed can be changed by hitting the<F12> key to Cancel
and then selecting
option 2.
6. If you need to change Ethernet standard you will have to type CRTLINETH and
create a new line description. For this help, consult your AS/400 administrator or
IBM. You can also try the IBM publication, "Getting Your AS/400 Working for You"
(SC41-5161-00), chapter 6.
Problem 4.3
Unable to connect the MinIT 6000 to the host and the AS/400 cannot ping the
MinIT6000. The AS/400 is at the latest PTF and CUM level and is able to ping other
devices. Also, your network administrator made sure the the IP addresses are correct.