Nortel Networks NN43001-563 Server User Manual


 
226 Install and configure IP Trunk 3.01 (and later) node
Prompt Response Description
It might be necessary to configure partial IP trunk cards
due to WAN traffic capacity limitations, or Leader and
DCHIP card real-time capacity for very large nodes and
networks.
TYPE TIE
TN XX XX Terminal number
l s c u Format for Large System, Call Server 1000E, and Media
Gateway 1000E, where l = loop, s = shelf, c = card, u = unit
cu
Format for Small System and Media Gateway 1000B
where c = card and u = unit
DES 16 character descriptive designator for the IP trunk card.
See Note 1
hhhh:hh:hh:hh:h
h
For unit 0. The IP trunk card ELAN network interface
MAC address.
xxx.xxx.xxx.xxx
For units 1 – 23. The IP trunk card ELAN network interface
IP address.
XTRK Extended Trunk Type: IP trunk card (1-slot or 2-slot
assembly).
MC32 Single slot, 32-port StrongArm (SA) processor Media
Card.
MC24 Double slot, 24-port Pentium processor Media Card.
MAXU
xx
Maximum number of ports on this IP trunk card,
where:
xx = 32 for the Media Card 32-port trunk card
xx = 24 for the ITG-Pentium 24-port trunk card
A warning message is printed if a number larger than 24
is entered for MAXU. Ignore this warning for the Media
Card 32-port trunk card.
CUST
xx
Customer number as defined in LD 15.
RTMB Route number and Member Number
0-511 1-4000
Range for Large System, Call Server 1000E, and Media
Gateway 1000E
0-127 1-4000
Range for Small System and Media Gateway 1000B.
Nortel Communication Server 1000
IP Trunk Fundamentals
NN43001-563 01.01 Standard
Release 5.0 30 May 2007
Copyright © 2007, Nortel Networks
.