Nortel Networks NN43001-563 Server User Manual


 
ITG-Pentium 24-port trunk card faceplate maintenance display codes 423
Code
Description
BIOS Card is running the ROM BIOS.
The card detected no valid IP Trunk 3.01 (and later) software
image or the JKL escape sequence was entered during
startup from the keyboard of a terminal connected to the local
maintenance port.
If the IP trunk card faceplate displays BIOS, it is not functioning
as an IP trunk card.
LDR Card is running active leader tasks.
BLDR Card has detected existing Active Leader and is running
Backup Leader tasks, or the card is configured as a Leader
and is missing its node properties. Transmit node properties
from TM 3.1.
FLR Card has detected the Active Leader and is running Follower
tasks.
In addition, if the IXP encounters any failures during its initialization, an
H:XX error code displays. The list of error codes is listed in Table 69 "List
of error codes" (page 423).
Table 69
List of error codes
Code
Description
H:00 Host Processor not booting
H:01 SDRAM test failure
H:02 SRAM test failure
H:04 PC Card device failure
H:08 Network interface failure
H:10 System interface failure
H:20 DSP interface failure
H:40 NVRAM/EEPROM interface failure
H:80 PCM connector failure
ITG-Pentium 24-port trunk card faceplate maintenance display codes
The maintenance display of the ITG-Pentium 24-port trunk card provides
startup codes, operating mode and error information on the functional card
state. Table 70 "ITG-Pentium 24-port trunk card faceplate maintenance
display message summary" (page 424) lists the startup codes and operating
mode codes.
Nortel Communication Server 1000
IP Trunk Fundamentals
NN43001-563 01.01 Standard
Release 5.0 30 May 2007
Copyright © 2007, Nortel Networks
.