Nortel Networks 15000 Network Router User Manual


 
Installing Power Supplies
308684-B Rev 00
3-15
3.
Using a Phillips screwdriver, remove the 2 screws that secure the strain
relief bracket to the terminal blocks (Figure 3-9)
.
Figure 3-9. Removing the Strain Relief Bracket
4.
Using a 5/32 in. hex wrench, loosen the screws on the terminal blocks
(Figure 3-10)
.
If you are connecting to a single power source, loosen the screws on the two
terminal block sections on the left labeled Input A in Figure 3-7
.
If you are connecting to both power sources, loosen the screws on all terminal
blocks.
Note:
This book refers to the two terminal block sections on the left (Input A)
as VDC-A and RTN-A. The two terminal block sections on the right (Input B)
are VDC-B and RTN-B.
Strain
relief bracket
VRS0053A
-VDC RTN -VDC RTN